Tag: AJR OnTrend

  • Nurse Practitioners, Physician Assistants Rarely Interpret Diagnostic Imaging Studies—Other than Radiography, Fluoroscopy

    Valeria Makeeva
    Corresponding Author

    Although Medicare claims data confirm the increasing role of nurse practitioners and physician assistants in imaging-guided procedures across the United States, nonphysician providers (NPPs) still rarely render diagnostic imaging services, compared with the overall number of diagnostic imaging interpretations. When NPPs do render diagnostic imaging services, though, said services are overwhelmingly radiography and fluoroscopy. Whereas considerable state-to-state variation exists in the rates in which NPPs render diagnostic imaging services, these rates are also uniformly low—likely due, in part, to unique scope-of-practice laws and regulations at the state level. “At present,” Emory University researcher Valeria Makeeva noted, “the near-term likelihood of NPPs appropriating substantial market share in diagnostic imaging is very low.” Utilizing 1994–2015 Medicare Physician/Supplier Procedure Summary Master Files, Makeeva and colleagues identified all diagnostic imaging services, including those billed by NPPs, and cataloged them by modality and body region. Then, using 2004–2015 Medicare Part B 5% Research Identifiable File Carrier Files, they separately assessed state-level variation in imaging services rendered by NPPs. Total and relative utilization rates were calculated annually. Nationally, between 1994 and 2015, diagnostic imaging services increased from 339,168 to 420,172 per 100,000 Medicare beneficiaries—an increase of 24%. During this same period, diagnostic imaging services rendered by NPPs increased 14,711% (from 36 to 5332 per 100,000 beneficiaries), yet still represented a mere 0.01% and 1.27% of all imaging in 1994 and 2015, respectively. Across all years, radiography and fluoroscopy constituted most of the NPP-billed imaging services and remained constant over time (e.g., 94% of all services billed in 1994 and 2015), representing only 0.01% and 2.1% of all Medicare radiography and fluoroscopy services. However, absolute annual service counts for NPP-billed radiography and fluoroscopy services increased from 10,899 to 1,665,929 services between 1994 and 2015.

  • Diagnostic Radiologists with Lifetime ABR Certificates Less Likely to Participate in MOC

    Andrew B. Rosenkrantz
    Corresponding Author

    Lifetime-certified diagnostic radiologists whose Maintenance of Certification (MOC) was not mandated by the American Board of Radiology (ABR) were far less likely to participate in ABR MOC programs—especially general radiologists and those working in smaller, nonacademic practices in states with lower population densities. Defining diagnostic radiologists as those whose only ABR certificate is in diagnostic radiology, lead author Andrew B. Rosenkrantz of NYU Langone Medical Center and colleagues cross-referenced Medicare and Medicaid data with ABR’s own public search engine to determine that 11,479 of 20,354 total diagnostic radiologists (56.4%) participated in MOC. Although diagnostic radiologists with time-limited certificates nearly universally participate in ABR MOC—99.6% (10,058/10,099)—participation rates were only 13.9% (1421/10,225) among the cohort with lifetime ABR certificates. “Many opinions have been expressed regarding MOC in radiology,” says Rosenkrantz, the 2017 ARRS Leonard Berlin Scholar. “But there is actually very little public data on the matter. Through this work, we hope to bring objective findings to help inform the discussions.” The rates of nonmandated participation were higher (all p < 0.001) for academic than for nonacademic radiologists (28.0% vs 11.3%), subspecialists than for generalists (17.0% vs 11.5%), and those in larger practice groups (< 10 members, 5.0%; 10–49 members, 12.6%; ≥ 50 members, 20.7%). State-level rates of nonmandated participation varied from 0.0% (South Dakota, Montana) to 32.6% (Virginia) and positively correlated with state population density (r = 0.315).

  • Gender Affirmation Surgery: A Primer on Imaging Correlates for the Radiologist

    Florence X. Doo
    Corresponding Author

    Since gender incongruence is now categorized as a sexual health condition, Florence X. Doo, Alexander S. Somwaru, and colleagues at Mount Sinai West in New York City contend that all subspecialties must be prepared to identify radiologic correlates and distinguish key postoperative variations in the three major categories of gender affirmation surgery: genital reconstruction, body contouring, and maxillofacial contouring. For trans-females, pelvic MRI remains the most reliable modality to evaluate the two most common complications arising from vaginoplasty: hematomas and fluid collection. Although vaginoplasty typically preserves the prostate, it may have atrophied from adjuvant hormonal therapy with estrogen and progesterone, so regular prostate cancer screening guidelines should still be followed. When evaluating urethral complications from phalloplasty in trans-males, for confirmation of stricture with abnormal function tests and for fistula evaluation, a retrograde urethrogram or voiding cystourethrogram can be obtained.

    Should a patient desire erectile potential with the fully-healed neophallus, an implant may be placed, which is prone to infection, attrition, malposition, and constituent separation. Related to gender affirmation surgery, silicone or saline breast implants in trans-females often evidence as incidental notations on chest radiography, CT, and MRI, yet the most common body contouring gender affirmation surgery is subcutaneous mastectomy. Since the nipple-areola complex is preserved, retaining malignant transformation risk, Doo et al. recommend trans-males submit to regular postsurgical breast cancer screening. Likewise, trans-female patients who have undergone neoadjuvant hormone replacement therapy have an increased risk for breast cancer and should be routinely screened. Illegal silicone injections, long targeted toward all transgender populations, typically register incidentally on imaging studies, as do facial augmentations achieved via neurotoxin injections or fillers, such as calcium hydroxylapatite or hyaluronic acid. As Doo and Somwaru explain, “postoperative imaging is not typically obtained because external aesthetic results can be adequately evaluated by the surgeon,” unless unique complications—bony erosions from impaction of alloplastic silicone prostheses or bone and cartilage autografts, embolization from injection or filler materials, etc.—present themselves.

  • Increasing Quality of Imaging Histories

    Richard E. Sharpe, Jr.
    Corresponding Author

    Collaborative research has not only standardized the definition of a complete imaging history, but also engineered systems to include supportive prompts in the order entry interface with a single keystroke—sustainably improving the overall quality of imaging histories. A Kaiser Permanente multidisciplinary team—physicians, both primary care and medical imaging providers, as well as information technology and practice improvement professionals—first defined the various components of a complete imaging history, a process that underwent several improvement cycles where consensus audits were regularly performed. The final apparatus of the collaborative team’s complete imaging history definition included the following responses: what happened; when it happened; where the patient was experiencing pain; and the ordering provider’s concern. These four prompts were then inserted into the electronic physician order entry process, and performance was monitored for an additional 18 months. From March 13, 2017, to December 16, 2018, 10,236 total orders were placed by ordering providers in the study clinic. Of the orders audited in the baseline period, 16.0% (64/397) contained all four history components, which increased to 52.0% (2200/4234; absolute increase of 36.0%, relative increase of 225.0%; p < 0.0001) in the subsequent time periods. Moreover, the mean number of characters ordering providers entered into the imaging histories they submitted increased from 45.4 characters per order during the baseline period to 75.4 (66.1% increase, p < 0.0001) after the intervention. “We have also noticed that increased clinical information results in radiologists feeling less of a need to recommend additional downstream or repeat imaging,” wrote Daniel S. Bor from Kaiser Permanente’s department of medical imaging. Bor noted, too, that the project team remains optimistic that the emergence of artificial intelligence could facilitate an automated method to improve imaging histories and support high-quality radiologist interpretations

  • Magnetic Eyelashes: A New Source of MRI Artifacts

    Alexander Mamourian
    Coauthor

    With U.S. sales of false eyelashes having increased 31% since 2017 and magnetic eyelashes trending as the top beauty-related Google search of 2018, Einat Slonimsky and Alexander Mamourian at Penn State Health utilized a phantom to show that magnetic eyelashes worn during MRI can cause substantial artifact and that detachment of the eyelashes from the phantom can occur. Using two sets of magnetic eyelashes from the same manufacturer that were randomly selected and purchased online, the phantom was created by drilling multiple 2-mm holes in a plastic container and then running monofilament line through these holes to create a grid. The two sets of eyelashes were attached to single nylon strings, placed diagonally within the phantom. The phantom was then submerged in a container filled with distilled water, covered with a layer of plastic film to prevent free movement of the lashes, should they detach. MRI was performed using a 3-T scanner with T2-weighted images, FLAIR images, T1-weighted images, susceptibility-weighted images, DW images, T1-weighted magnetization-prepared rapid-acquisition gradient-echo images, and T2-weighted sampling perfection with application-optimized contrasts using different flip-angle evolutions. Ultimately, the magnetic eyelashes evidenced an artifact much larger than that created by the control aneurysm clips (two made of cobalt alloy, one made of titanium) using the same sequences—measuring 7 × 6 cm maximal on susceptibility-weighted images, obscuring the entire phantom. Although the eyelashes stayed attached to the strings during the scan, upon removal of the phantom from the bore, one set of eyelashes detached from its string. Restrained by the plastic covering, it became attracted to the other eyelashes still attached to the phantom. “We strongly recommend inserting a line about magnetic eyelashes on the MRI safety questionnaire and adding stops in the screening system to prevent the entry of anyone with these lashes, including staff, into the MRI scanner room,” Slonimsky and Mamourian wrote.

  • Aspirin and Embolization of Hepatocellular Carcinoma

    F. Edward Boas
    Corresponding Author

    Aspirin therapy is associated with both improved liver function test results and survival after transarterial embolization (TAE) for hepatocellular carcinoma (HCC), according to a retrospective review of 304 patients led by F. Edward Boas at Memorial Sloan Kettering Cancer Center in New York City. Among the 42 patients taking aspirin at the time of initial TAE for HCC, bilirubin level evidenced lower 1 day (0.9 vs 1.3, p < 0.001), 1 month (0.9 vs 1.2, p = 0.048), and 1 year (0.8 vs 1.0, p = 0.021) post-embolization. “Although the differences in liver function test results in the groups taking and not taking aspirin were small,” wrote Boas, “standard biochemical liver function tests are insensitive to early cirrhotic changes.” Clarifying further, Boas noted, “small changes in biochemical liver function test results might underestimate the degree of liver injury after embolization.” Whereas aspirin use indicated no disparity in initial response rate (88% vs 90% complete response or partial response, p = 0.59), median time to progression (6.2 vs 5.2 months, p = 0.42), initial site of progression (p = 0.77), or fraction of patients dying with disease progression (88% vs 89%, p = 1.00), the median overall survival period after TAE for HCC measured longer for the cohort taking aspirin (57 vs 23 months, p = 0.008). Despite comparable liver function, American Joint Committee on Cancer stage, comorbidities, and other clinical characteristics before embolization in both groups, because his study was retrospective, Boas acknowledged that a confounding variable may account for the improved survival among patients taking aspirin.

  • Quantifying the Severity of Parkinson Disease

    Pathologically, Parkinson disease is characterized by a loss of dopaminergic neurons in the substantia nigra pars compacta (SNpc) area of the brain, resulting in presynaptic nigrostriatal dopamine dysfunction. Whereas prior research into dopaminergic neuroimaging has illustrated the independent utility of neuromelanin MRI and dopamine transporter SPECT for evaluating the severity of Parkinson disease, Hiroto Takahashi and colleagues from Japan’s Osaka University Graduate School of Medicine aimed to explore the use of these two imaging biomarkers to quantify severity during the progression of Parkinson disease. Twenty men and 20 women (mean age 68.35 years) who underwent neuromelanin MRI and dopamine transporter SPECT were included in the study. Parkinson disease severity was assessed with the Hoehn and Yahr (HY) scale (HY stage 1, 4 patients; stage 2, 18 patients; stage 3, 8 patients; stage 4, 6 patients; stage 5, 4 patients). The signal-to-noise ratio (SNR) in the SNpc on neuromelanin MR images and the striatal specific binding ratio (SBR) on dopamine transporter SPECT images were calculated based on the value of each background region. The Mann-Whitney U test was used to assess the significance of differences between the early-stage group (HY 1 and 2) and the advanced-stage group (HY 3–5) for each SNR and SBR. Overall, both SNR and SBR measured much greater in early-stage patients compared to the advanced stage group (p < 0.05). Additionally, the AUC for differentiating early and advanced stage groups was 0.73 for SNR and 0.89 for SBR. The coefficient of correlation was −0.47 for SNR versus HY stage and −0.67 for SBR versus HY stage. As Takahashi acknowledged, “The current study shows that it is possible to quantify the degeneration of dopaminergic nigrostriatal transporters in Parkinson disease using striatal SBR derived from dopamine transporter SPECT with good correlation with the HY stage.”

  • Optimization of MRI Turnaround Times

    Michael Recht
    Corresponding Author

    One topic that has the potential to drastically improve the value of MRI (but has not been researched as thoroughly as hardware application and software innovation) is the optimization of MRI workflow. The construction of a new outpatient imaging center at NYU Langone Health to house 1.5- and 3-T scanners provided Dr. Michael Recht and colleagues an opportunity to reengineer their MRI turnaround time (i.e., “the interval between completion of the last sequence acquisition for one patient and initiation of the first sequence acquisition for the next patient”). A process improvement team comprised of different stakeholders—radiologists, MRI technologists, IT administrators, front desk personnel, real estate and development staff—met biweekly for several months to define the current workflow and its limitations and to determine optimizations, such as the use of dockable tables, dedicated patient preparation rooms, two doors in each MRI room, positioning the scanner to provide the most direct path to the scanner, and coil storage in the preparation rooms with duplication of the most frequently used coils. Once construction and a two-month training period were completed, mean and median turnaround times were measured for each scanner at NYU Langone’s new facility, as well as for six scanners with differing magnets at two existing outpatient centers from March 1, 2018 to June 30, 2018. When patients were properly prepared and on their docking tables, the authors found the difference in mean turnaround time was 328 seconds, “which is greater than the goal of five minutes of time saved,” Recht wrote. For all patients, including those who were not ready when the prior patient’s examination was finished, the improvement in mean turnaround time was 265 seconds. Interestingly, the difference in median turnaround times for all patients clocked in at 340 seconds. “Five minutes might not seem like much time,” Aunt Minnie added, “but taking 300 fewer seconds to turn around an MRI suite to accommodate the next case can improve workflow, better serve patients, and add to a facility’s coffers.”